Bridge Repair and Coating – A case study


 August 20, 2020. 1:31 PM

Introduction:

All the structures in the road system must be well conserved to avoid compromising design responsibility, safety when the structures are in use and the implementation of maintenance operations. If the condition of a structure is not well monitored, it will be subject to such a degree of deterioration that normal maintenance operations will no longer be enough, and it will be necessary to carry out a more complex and heavier intervention, at a much higher cost. One way of preventing such problems is to have a detailed inspection programme which periodically singles out maintenance operations required on the structures, thus guaranteeing, apart from the safety of road-users, lower overall maintenance costs.

One of the most important parts of assessing the state of deterioration is a visual inspection, which also singles out the causes of the deterioration:  
  • intensity of circulating traffic;
  • aggressive environment;
  • climatic factors;
  • excessive loads;
  • occasional impacts;
  • insufficient drainage system for rainwater.
Amongst all the possible causes of deterioration, road decks suffer most from the effects of atmospheric agents and the presence of water in general. Water due to atmospheric phenomena, with a certain level of pollution and, very often, the presence of de-icing salts, are extremely aggressive for concrete, as are thermal cycles both during the day and night, and during the different seasons of the year. The deterioration of concrete shows up in a number of ways, with the progressive erosion and crumbling of the surface, corrosion of the metal reinforcement and the formation of rust, swelling of the cortex area of the concrete, etc.

Apart from the different causes of deterioration, the problem often shows up at different times, which is why all the structures must be carefully checked on a regular basis in order to identify both routine maintenance and extra maintenance requirements.

Below is a list of methods for the repair of bridges and viaducts:

• Preparation of the substrate;

• Protection of reinforcement rods;

• Positioning new reinforcement;

• Repairing concrete using thixotropic mortar;

• Repairing concrete using castable mortar;

• Repairing concrete using cementitious binders;

• Smoothing off concrete surfaces;

• Protecting and decorating concrete structures.

Each of these methods require different types of products, which are all suitable for achieving the required result, and the choice of which one of these to use depends on the location, the thicknesses to be repaired, on-site organisation, etc.

To make sure that repair work is efficient and long-lasting, having the most suitable products

available is not always sufficient. Deterioration to a structure may be due to a multitude of causes, and only if these causes are well known, may we be sure that repair work will be resistant and long-lasting. Regarding this issue, the diagnosis of deterioration is a fundamental phase in the list of operations to be carried out.

Through a detailed analysis of a structure it is possible, and also absolutely essential, to define the type of aggression, the penetration depth of polluting agents and the characteristics of the concrete used for the structure. After these operations, it is then possible to carry out the repair work.

Background

In 1962 the Province of Zeeland – an area in the south-western part of the Netherlands – decided to build a quick connection between the isles Noord-Beverland and Schouwen-Duiveland with the industrial area around the city Vlissingen-Oost, which was then going through a period of strong development. At the time, work on the Delta Plan project – a series of construction projects consisting of dams and infrastructures which have been protecting coastal areas from flooding since 1953 – was still in full swing. The Province of Zeeland, however, decided not to wait for the Oosterschelde dam to be built, which was to include a new road connecting various local towns, and went ahead on their own. The dam was completed in 1987, whereas the Zeeland Bridge had already been in service for more than twenty years: construction work on the bridge started in 1962 and it was inaugurated by Queen Juliana of the Netherlands on the 15th of December, 1965. 

In order to recover the cost of the work, which had not received any form of state funding, from the inauguration date until the 31st of December 1992 anybody using the bridge, including pedestrians, cyclists and bus passengers, were required to pay a toll. In 2000 the road received a major overhaul to make it safer and bring it in line with the latest highway regulations and work included replacing the old guardrails on both sides of the road with concrete barriers and the introduction of a by-law that prohibited overtaking. On the 15th of December, 2015, the Zeeland Bridge was declared a Monument of National Interest by the Netherlands National Cultural Heritage Agency. The Zeeland Bridge is an imposing, 5,002-m-long structure and, up until the inauguration of the Öland Bridge in Sweden (6,072 metres long), it was the longest bridge in Europe. It is made up of 54 pillars and 52 spans of 95 m and has a mobile section 40 m long. The Zeeland Bridge, which has two lanes and a cycle lane, is suspended over the water and its entire length is supported by pillars in the form of an upside-down “V” placed on reinforced concrete bases which, in turn, sit on the seabed. The bases are of different lengths. Where the water is particularly deep they are 60 m long, while in other areas they are up to 30 m long. The bridge also has many different parts that are connected together by strong steel cables for a total length of 300 km. 

The bridge is exposed all day and all night to the effects of the sun, winds and, above all, the sea, as well as carbon dioxide emissions from passing vehicles, which means it needs to be constantly and methodically checked and maintained. New coloured coating is applied to the pillars every 10 years and the products used are evaluated to check their adhesion properties when applied to the substrate, their durability, the stability of their colour and their resistance to atmospheric agents. In 2016 the owners of the bridge tested a number of products from different manufacturers on the surface of some of the pillars, including products proposed by Mapei. After 6 months the product that had demonstrated the best performance characteristics in terms of adhesion, flexibility, resistance and colour maintenance was ELASTOCOLOR WATERPROOF acrylic paint, a Waterproofing Product for permanent contact with water, which is easy to clean and resistant to all types of atmospheric phenomena and smog. 

Before proceeding with painting the pillars, the concrete on some of the pillars was found to be badly deteriorated. Mapei Technical Services recommended removing the deteriorated areas until the reinforcing rods were exposed. It was recommended to apply two coats of MAPEFER 1K one-component, protective mortar on the reinforcing rods.

Once MAPEFER 1K had dried, the surface of the pillars was repaired with PLANITOP SMOOTH & REPAIR R4 structural, rapid-setting, shrinkage-compensated, thixotropic, fibre-reinforced mortar. The pillars were then finished off by applying two coats of ELASTOCOLOR WATERPROOF.

Information about products:

Product Name

Description

Elastocolor Waterproof

A flexible, protective paint for outdoor applications made from acrylic resin in water dispersion

Mapefer 1K

One-component corrosion-inhibiting cement mortar for the protection of reinforcing rods

Planitop Smooth and Repair R4

one-component, thixotropic mortar with very low emission of volatile organic compounds (EMICODE EC1 R Plus)


image3

image1

image2

image4

Products mentioned in the article

MAPEFER 1K
MAPEFER 1K
One-component, anti-corrosion cementitious mortar for steel reinforcement rods. TECHNICAL DATA: Maximum dimension of aggregate: 0.5 mm.…
ELASTOCOLOR WATERPROOF
ELASTOCOLOR WATERPROOF
Waterproof, easy-to-clean acrylic paint for internal and external surfaces in permanent contact with water. TECHNICAL DATA: Consistency:…

Comments

Load more comments

Login or Register
to MyMapei Area to insert your comment

Keep in touch

Subscribe to our newsletter to get Mapei news